AUD-02
Speaker & Coax Cable Sizing
IEC 60268 · NEC 725 · NEC 820 · NEC 310.15(B) · ANSI/AVIXA A102.01
Capacity and layout
The drawing appears when the inputs are complete
- 01Size loudspeaker cable from run length, load impedance, acceptable power loss and required damping factor, or check coaxial RF/SDI attenuation against a length and frequency.
- 02Tip. On low-impedance runs, damping factor usually demands a heavier conductor than power loss does. Cable resistance sits in series with the loudspeaker, so it degrades the amplifier’s control of the cone long before it wastes an audible amount of power.
- 030.5 dB — Common loss budget
- 0470.7 / 100 V — Constant-voltage lines
- 05≥ 20 : 1 — Damping factor target
- 065 % — Loss at 0.22 dB
Conductor sizing and signal loss
Cable resistance sits in series with the load, so it both wastes power and degrades the amplifier’s control over the loudspeaker. Two independent criteria therefore apply to every run, and the larger conductor of the two wins. Coaxial runs face a different limit: attenuation that rises with frequency and length.
Loudspeaker cable
Low-impedance runs are usually governed by damping factor rather than by power loss. Constant-voltage lines are transformer-coupled, so only loss applies.
Use cases
- 0.5 dB — broadcast and critical listening
- 1 dB — general AV and commercial (AVIXA)
- 2 dB — background music and paging
- 70 V / 100 V lines — loss only, damping not meaningful
Formula
Max loop resistance = Z × (10^(dB ÷ 20) − 1)
IEC 60268 · NEC 640/725
Coaxial cable
Attenuation in coax rises with the square root of frequency and linearly with length, so the highest frequency carried sets the maximum run.
Use cases
- SDI and RF runs — check at the highest carried frequency
- Longer runs need lower-loss cable, not more power
- Return loss and impedance match matter as much as length
- NEC Article 820 governs coaxial installation
Formula
Loss (dB) = attenuation per 100 m × length ÷ 100
NEC 820
NEC classification depends on the amplifier, not the cable. Wiring is Class 2 only where the amplifier is a listed Class 2 source (≤ 100 VA at ≤ 30 V); most professional amplifiers exceed that, which makes the run Article 640 audio distribution wiring instead. Confirm the amplifier listing before selecting cable to a class.
- 01Loudspeaker sensitivity and rated power — IEC 60268
- 02Class 2 and Class 3 circuits — NEC 725
- 03Coaxial distribution — NEC 820
- 04Conductor ampacity and derating — NEC 310.15(B)
- 05Coverage and level uniformity — ANSI/AVIXA A102.01