How the
calculations
are derived
Every figure traces back to a published document. Nothing here is a house rule dressed up as a standard, and where a value is a planning assumption rather than a requirement the app says so on the face of the report.
This is not a certified or independently audited product, and it does not replace a qualified designer’s judgement.
Image and display
- Display sizing (BDM & ADM)
- ANSI/AVIXA V202.01 (DISCAS)
- Display Size (AVIXA DISCAS)Display Viewing AngleProjector Brightness & ThrowDvLED Pixel PitchVideo Wall Builder
- Image contrast, all four viewing categories
- ANSI/AVIXA V201.01 (ISCR)
- Display Size (AVIXA DISCAS)Display Viewing AngleDisplay Brightness (AVIXA ISCR)Projector Brightness & ThrowDvLED Pixel PitchVideo Wall Builder
- Performance verification
- ANSI/AVIXA D401.01
- Display Size (AVIXA DISCAS)Display Viewing AngleDisplay Brightness (AVIXA ISCR)Projector Brightness & ThrowDvLED Pixel PitchVideo Wall BuilderVideo Wall Controller CapacityCamera Distance (IEC 62676-4 DORI)DSP System & Gain Structure
- Commissioning and acceptance
- ANSI/AVIXA D402.02
- Display Brightness (AVIXA ISCR)Video Wall BuilderVideo Wall Controller Capacity
Audio
- Coverage uniformity in listener areas
- ANSI/AVIXA A102.01
- Speaker DesignSpeaker & Coax Cable SizingAudio Data Rate & Wavelength
- Dynamic range in listener areas
- ANSI/AVIXA A104.01
- Speaker DesignDSP System & Gain StructureAudio Data Rate & Wavelength
- Loudspeaker sensitivity and rated power
- IEC 60268
- Speaker DesignSpeaker & Coax Cable SizingDSP System & Gain StructureAudio Data Rate & Wavelength
Network and transport
- Uncompressed video over IP
- SMPTE ST 2110
- AVoIP Bandwidth & Switch TopologyVideo Wall Controller CapacityIP Table Generator
- ICT design for intelligent buildings
- ANSI/BICSI 007-2024
- AVoIP Bandwidth & Switch TopologyPoE BudgetWi-Fi Coverage & CapacityIP Table GeneratorRack Builder (EIA-310-E)Rack Cooling (ASHRAE)UPS Sizing
Electrical and containment
- Conductor ampacity and derating
- NEC 310.15(B)
- Speaker & Coax Cable SizingRack Builder (EIA-310-E)Rack Cooling (ASHRAE)
- Class 2 and Class 3 circuits
- NEC 725
- Speaker & Coax Cable SizingPoE BudgetCable Conduit Capacity (NEC)
Space, furniture and life safety
- Assembly seating, row spacing and egress
- IBC 1029; NFPA 101
- Reference only
- Chair and work surface dimensions
- BS EN 1335; BS EN 527
- Reference only
- Equipment room cooling
- ASHRAE thermal guidelines
- DvLED Pixel PitchPoE BudgetRack Builder (EIA-310-E)Rack Cooling (ASHRAE)UPS Sizing
In every report
The PDF each calculator produces carries a matrix showing which document was applied to which part of that specific design, generated from the result rows actually used — so a reviewing consultant can follow your reasoning rather than take it on trust. Rows derived from a planning assumption rather than a requirement are marked as such, both on screen and in the report.
Several of these documents are paywalled. The formulas implemented here are their well-established public form — the arithmetic practising CTS-D designers use — and every result cites the governing document. Where a design decision turns on an exact threshold, consult the standard itself.